To enter the QC Test Mode, press the Power button while holding the
Buzzer and Wrinkle Care buttons. After entering the QC Test Mode, step
through the tests below by pressing the Start/Pause button.
End QC Test mode9
No ELB (Earth Leakage Breaker)
Motor off, Buzzer on8
Moisture data (Normal: 221) by
semiconductor moisture sensor.
Motor off 7
Moisture data (Normal: 230-245).
(For moisture sensor check on production
line by opening door with door switch
pressed.)
Motor on (CW)6
Moisture data (Normal: 230-245)Pump on, Motor off5
Temperature at high temp
thermistor located in heater
Motor on (CW)
both heating coils on
4
Temperature at the low temp
thermistor under the door
Motor on (CW)
1750W heater on
3
Moisture data (Normal: 230-245)
Motor on (CW), Humidity data2
Moisture data (Normal: 230-245)
Motor on (CCW), Humidity data1
Programming checksumLEDs0
DisplayCheckpoint
Start/Pause
___ times
Note: This information was verified on an early production dryer. The sequence of operations may
vary on the particular dryer being serviced.
Test Mode