29
󳥎
Test 7
GAS Valve test - Gas Type
Caution
Trouble Symptom
Measurement Condition
When measuring power, be sure to wear insulated gloves, to avoid electric shock.
While operating, Heating will not work.
Drying time takes longer.
With dryer power on
Harness check
Controller change
When measuring terminal resistance on Valve 1 and
Valve 2, Valves are more than1.5 ~ 2.5k?
(Measure after Off )
NO
YES
Change Valve
Change Valve
Check thermostat
Hi limit Safety
Igniter operates?
(after 1 min, Igniter becomes reddish)
YES
NO
Check Igniter &
Frame detect
When measuring Valve 2 voltage, Value is more
than DC 90V? (10 sec after Igniter off)
NO
YES
Check Gas
connection or
Gas supply
When measuring Valve 1 voltage,
More than DC 90V?
YES
NO
If Valve 1 and Valve 2 are under DC 10V, Valves
are Off?
YES
NO
Power On & Start (Normal Cycle)
NO
Igniter
Valve 2
Valve 1