NO
Are the resistance of the Hall S ens or5~15k ?
Motor Locked Error (LE)
[P re C heck]
•G entle wash cycles , s uch as P erm P ress, Delicates, Hand Was h, and Wool/S ilk s hould only be used for s maller loads.
B ecause these cycles are more gentle in tumbling and s pinning, putting too much in the drum can register an issue
with the motor. R emove items , res et unit and tes t with a R inse/S pin cycle.
•Don’t replace the P C B , when the hall sens or is replaced.
R eplace the P C B , when the LE is displayed
after replacing the hal
l sensor.
Is the C onnec tor connected correctly to
the
Main P C Band the Motor?
Or is the
Harnes s alright ?
Y E S
NO
Y E S
Y E S
Y E S
Y E S
NO
Disas semble the R otor.
Are the
Magnet of rotor cracked or broken?
•Ha ~ C ommon
: 5 ~ 15 k
•Hb ~ C ommon
: 5 ~ 15 k
R eplace the
Main P C B
.
P ress the P ower button & S tart / P aus e button.
Does the
Drum s top when the start / pause button is pres sed to start the cycle ?
Or S ometimes does the
Drum rotate weakly (under 15rpm)?
Magnet
Ha
Hb
C ommon
Are the resistance s ame
between
S tator points ?
V~U / U~W / W~V : 8~11
V U W
V U W
R econnect or repair the C onnector.
Or replace the
Harnes s .
R eplace the R otor.
R eplace the Hall S ens or.
Disas semble
hall s ens orcarefully.
(Next page)
NO
R eplace the S tator .