Is the res istance of the Thermis tor out of range
2.5~180K at 105~0°C ?
Disas semble the C abinet cover and C ondens ing
B ellows
.
Is there any foreign object in
C ondens ing B ellows ?
Disas semble the Dry Fan A s s y and Dry Duct Upper,
and clean foreign object in Duct and F an.
Is the C onnec tor connected correctly to
the
Main P C B and the Dry Heater or F an Motor?
Or is the
Harnes s alright?
R econnect or repair the C onnector.
Or replace the
Harnes s .
R eplace the Thermis tor.
C lean the B ellows .
Y E S
NO
C heck for Dry Heater trouble. Page 24
C heck for Dry Fan Motor trouble. P age 25
Dry Heater Error (dHE)
Y E S
Y E S
NO
NO
Y E S
Y E S