80
REGULAR MAINTENANCE
ENGLISH
Cylinder number 1 2 3 4
Valve
Air
intake
Exhaust
Air
intake
Exhaust
Air
intake
Exhaust
Air
intake
Exhaust
Top dead center of cylinder 1
Top dead center of cylinder 1
3) After adjustment
Put the engine rocker cover and the high-tension wire back together.
(Rocker cover tightening torque: 10.8~12.8N·m / 1.1~1.3 kg·m)
Check the engine operation
Flip on the ENG_STOP switch(SW02) and the GAS OFF selecting switch(SW01) located in the
external board of the outdoor unit control panel towards the Upwardto turn ON. Check for any
abnormal sound during the operation.
If there is an abnormal sound, check the engine operation again.