To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
6. TROUBLESHOOTING
- 10 -
1-
-
2-
3-
4-
5-
2-
5-
5-
3-
5-
4-
5-
5-
1-
-
4-3-
YES-
YES-
YES-
YES-
NO-
NO-
YES-
YES-
YES-
NO-
NO-
NO-
Power Source.
No Voltage.
(Rating Voltage
±10%)?
Replace OLP.
Reconnect.
Replace
PTC-Starter.
Replace OLP.
O.K.
Check connection
condition.
OLP disconnected?
Advise the customer
to use a regular
TRANS.
Replace Compressor.
OLP works within
30 sec. in forcible OLP
operation by turning
instant power on and
off.
Components start in
the voltage of Rating
Voltage ±10%
below.
Applied voltage isn't
in the range of Rating
Voltage ±10%.
Remove the PTC-
Starter from the
Compressor and
measure the voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.
Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.
Check the resistance
of two terminals in
PTC-Starter.
Check if applying
a regular OLP.
Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.
Check the
resistance of
Motor
Compressor.
Check the
resistance of
PTC-Starter.
Check OLP.
Check
starting state.