3. SENSOR RESISTANCE CHARACTERISTICS TABLE
• The tolerance of sensor resistance is ±5%.
• Be sure to measure the sensor resistance after keeping the sensor more than 3 minutes at a measuring temperature.
(It needs delay due to sensor speed.)
• Measure the resistances of SENSORs with a digital tester after disconnecting CON 3 of MAIN PWB ASSY.
- 29 -
MEASURED TEMPERATURE
RESISTANCE OF FREEZER SENSOR RESISTANCE OF DEFROST SENSOR, ROOM TEMPERATURE SENSOR
-20°C 22.3k 77k
-15°C 16.9k 60k
-10°C 13.0k 47.3k
-5°C 10.1k 38.4k
0°C 7.8k 30k
+5°C 6.2k 24.1k
+10°C 4.9k 19.5k
+15°C 3.9k 15.9k
+20°C 3.1k 13k
+25°C 2.5k 11k
+30°C 2.0k 8.9k
+40°C 1.4k 6.2k
+50°C 0.8k 4.3k