5. DISPENSER
1) Disconnect button assembly by pulling down until it
stops and then pulling forward.
2) Remove display frame Assy by making a gap between a
display frame Assy. and funnel Assy. with a balde
screwdriver and pulling it forward. The cover dispenser
is fixed with a hook.
3) Display Assy can be disconnected by pressing the
upper part of a cover dispenser and pushing a display
Assy. after disconnecting display frame Assy. housing.
4) Loosen four screws with a phillips screwdriver and pull a
funnel Assy to disconnect.
5) Duct cap Assy is disconnected if hold lever connecting
screw is loosened with a phillips screwdriver.
6) For assembling a duct cap Assy., insert one end of a
spring into the right hole of dispenser lever, and insert
the other end into the right hole in upper part of
dispenser. And then assemble a holder lever after fixing
a holder at a solenoid Assy working part.
HOW TO DISASSEMBLE AND ASSEMBLE
- 107 -
Button
Funnel Assy
Funnel
Assy
Holder
Lever
Solenoid Assy
Cap Assy,Duct
Spring
Heater, Sheet
Lever,Dispenser
Solenoid Assy