EasyManua.ls Logo

LG GR-B197DVCA - Page 39

LG GR-B197DVCA
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2) GR-B197, GR-B207, GR-B247
The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting
temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or
an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every
temperature sensor is as follows:
EXPLATION FOR MICOM CIRCUIT
- 39 -
SENSOR CHECK POINT
NORMAL(-30 °C ~ 50 °C) IN
SHORT IN OPEN
Freezing sensor POINT A Voltage
Frost removal sensor POINT B Voltage
Cold storage sensor 1 POINT C Voltage 0.5 V~4.5 V 0 V 5 V
Cold storage sensor 2 POINT D Voltage
Room temperature sensor POINT E Voltage