2-7. Electric Equipment Sequential Operation
Electric equipment such as compressor, defrost heater, cooling fan, step motor damper, etc. operates in the following
sequence when power is initially applied and test is completed in order to reduce noise and parts damage.
MICOM FUNCTION
- 27 -
Function Operation Sequence Remarks
When power is initially applied TEST MODE
Defrost sensor
temperature is
above 10 °C
(purchased or
house-moving)
If there is any error in
functions, initial
starting does not
work.
If switch is pressed
one more or defrost
sensor temperature
is above +5 °C, it
returns to test mode
and restarts.
(compressor shall
operate after 7
minutes)
Defrost sensor
temperature is
below 10 °C
(power cut or
service)
Test Mode 1
(Forced Start)
Test Mode 2
(Check Freezer
fan )
Test Mode 3
(Forced defrost)