2. Sensor Resistance Characteristic Table
• Tolerance of sensor resistance is ±5 %.
• Leave the sensor at measuring temperature for more than 3 minutes when measuring sensor resistance.
(necessary due to detecting speed)
• It is desirable to use digital tester as analogue tester has wider measuring temperature.
• Disassemble refrigerator sensor 1 and 2 from CON8 of main PWB assembly and measure it with digital tester.
• Disassemble freezer sensor from CON7 of main PWB assembly and measure it with digital tester.
MICOM CIRCUIT DESCRIPTION
- 49 -
Measured Temperature (°C) Freezer Sensor
Refrigerator Sensor 1 and 2, Defrost Sensor and
Open Air Sensor
-20 °C 22.3 kΩ 77 kΩ
-15 °C 16.9 kΩ 60 kΩ
-15 °C 13.0 kΩ 47.3 kΩ
-5 °C 10.1 kΩ 38.4 kΩ
0 °C 7.8 kΩ 30 kΩ
+5 °C 6.2 kΩ 24.1 kΩ
+10 °C 4.9 kΩ 19.5 kΩ
+15 °C 3.9 kΩ 15.9 kΩ
+20 °C 3.1 kΩ 13 kΩ
+25 °C 2.5 kΩ 11 kΩ
+30 °C 2.0 kΩ 8.9 kΩ
+40 °C 1.4 kΩ 6.2 kΩ
+50 °C 0.8 kΩ 4.3 kΩ