EasyManua.ls Logo

LG GR-B197WVS - Sensor Resistance Characteristic Tabie

LG GR-B197WVS
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Sensor Resistance Characteristic Table
Tolerance of sensor resistance is ±5 %.
Leave the sensor at measuring temperature for more than 3 minutes when measuring sensor resistance.
(necessary due to detecting speed)
It is desirable to use digital tester as analogue tester has wider measuring temperature.
Disassemble refrigerator sensor 1 and 2 from CON8 of main PWB assembly and measure it with digital tester.
Disassemble freezer sensor from CON7 of main PWB assembly and measure it with digital tester.
MICOM CIRCUIT DESCRIPTION
- 49 -
Measured Temperature (°C) Freezer Sensor
Refrigerator Sensor 1 and 2, Defrost Sensor and
Open Air Sensor
-20 °C 22.3 k 77 k
-15 °C 16.9 k 60 k
-15 °C 13.0 k 47.3 k
-5 °C 10.1 k 38.4 k
0 °C 7.8 k 30 k
+5 °C 6.2 k 24.1 k
+10 °C 4.9 k 19.5 k
+15 °C 3.9 k 15.9 k
+20 °C 3.1 k 13 k
+25 °C 2.5 k 11 k
+30 °C 2.0 k 8.9 k
+40 °C 1.4 k 6.2 k
+50 °C 0.8 k 4.3 k

Other manuals for LG GR-B197WVS