3-2.  Summary Of Heavy Repair 
TROUBLE DIAGNOSIS
- 95 -
Process Contents Tools
- Cut charging pipe ends and discharge refrigerant from  Filter, side cutters
drier and compressor.
- Use R134a oil and refrigerant for compressor and drier Pipe Cutter, Gas welder, N
2 gas
- Confirm N
2 sealing and packing conditions before use.
Use good one for welding and assembly.
- Weld under nitrogen gas atmosphere.(N
2 gas pressure:
0.1-0.2kg/cm
2
).
- Repair in a clean and dry place.
- Evacuate for more than forty minutes after connecting  Vacuum pump(R134a 
manifold gauge hose and vacuum pump to high (drier)  exclusively), Manifold gauge.
and low (compressor refrigerant discharging parts) 
pressure sides.
- Evacuation Speed:113l/min.
- Weigh and control the allowance of R134a bombe in a  R134a exclusive bombe(mass 
vacuum conditions to be ±5 g with electronic scales and  cylinder), refrigerant(R134a)
charge through compressor inlet manifold gauge, electronic
(Charge while refrigerator operates). scales, punching off flier,
- Weld carefully after inlet pinching. gas welding machine
- Check leak at weld joints. Electronic Leak Detector,
Minute leak: Use electronic leak detector Driver(Ruler).
Big leak: Check visually or fingers.
Note:Do not use soapy water for check.
- Check cooling capacity
➀ Check radiator manually to see if warm.
➁ Check hot line pipe manually to see if warm.
➂ Check frost formation on the whole surface of the
evaporator.
- Remove flux from the silver weld  joints with soft brush  Copper brush, Rag, Tool box
or wet rag.(Flux may be the cause of corrosion and 
leaks.)
- Clean R134a exclusive tools and store them in a clean 
tool box or in their place.
- Installation should be conducted in accordance with the 
standard installation procedure.(Leave space of more 
than 5 cm from the wall for compressor compartment 
cooling fan mounted model.)
Trouble
diagnosis
Remove refrigerant
Residuals
Parts
replacement
and welding
Compressor
compartment
and tools
arrangement
Transportation
and
installation
Check
refrigerant leak
and cooling
capacity
Vacuum
Refrigerant
charging and
charging
inlet welding