7-2-7 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING COMPENSATION CIRCUIT
1. Refrigerator Temperature Compensation
2. The temperature compensation for refrigerator compartment is in the following Table.
This circuit is aimed to input the necessary temperature compensation values into the MICOM in order to adjust the
refrigerator temperature which is different in each model.
- 27 -
Refrigerator
Resistance Temperature Remark
(RCR) Compensation
180 K +2.5 °C Compensation by
56 K +2.0 °C
raising the
33 K +1.5 °C
temperature
18 K +1.0 °C
12 K +0.5 °C
10 K 0 °C
Standard Temperature
8.2 K -0.5 °C Compensation by
5.6 K -1.0 °C
lowering the
3.3 K -1.5 °C
temperature
2 K -2.0 °C
470 K -2.5 °C
Revised resistance
470 2k 3.3k 5.6k 8.2k 10k 12k 18k 33k 56k 180k
Present resistance
No 0.5°C1°C 1.5°C2°C 2.5°C3°C 3.5°C4°C 4.5°C5°C
470 change Up Up Up Up Up Up Up Up Up Up
0.5°C No 0.5°C1°C 1.5°C2°C 2.5°C3°C 3.5°C4°C 4.5°C
2k Down Change Up Up Up Up Up Up Up Up Up
1°C 0.5°C No 0.5°C1°C 1.5°C2°C 2.5°C3°C 3.5°C4°C
3.3k Down Down Change Up Up Up Up Up Up Up Up
1.5°C1°C 0.5°C No 0.5°C1°C 1.5°C2°C 2.5°C3°C 3.5°C
5.6k Down Down Down Change Up Up Up Up Up Up Up
2°C 1.5°C1°C 0.5° No 0.5°C1°C 1.5°C2°C 2.5°C3°C
8.2k Down Down Down Down Change Up Up Up Up Up Up
Refrigerator 2.5°C2°C 1.5°C1°C 0.5°C No 0.5°C1°C 1.5°C2°C 2.5°C
(RCR) 10k Down Down Down Down Down Change Up Up Up Up Up
3°C 2.5°C2°C 1.5°C1°C 0.5°C No 0.5°C1°C 1.5°C2°C
12k Down Down Down Down Down Down Change Up Up Up Up
3.5°C3°C 2.5°C2°C 1.5°C1°C 0.5°C No 0.5°C1°C 1.5°C
18k Down Down Down Down Down Down Down Change Up Up Up
4°C 3.5°C3°C 2.5°C2°C 1.5°C1°C 0.5°C No 0.5°C1°C
33k Down Down Down Down Down Down Down Down Change Up Up
4.5°C4°C 3.5°C3°C 2.5°C2°C 1.5°C1°C 0.5°C No 0.5°C
56k Down Down Down Down Down Down Down Down Down Change Up
5°C 4.5°C4°C 3.5°C3°C 2.5°C2°C 1.5°C1°C 0.5°CNo
180k Down Down Down Down Down Down Down Down Down Down Change
Table of Temperature Compensation by adjusting the
resistance (Difference with the current temperature)
E.g.) If the refrigerator compensation resistance (RCR)
is changed from 10K (the current resistance) to
18K (the adjustment resistance), the temperature
of the refrigerator rises +1 °C.
<LCD MODEL>