EasyManua.ls Logo

LG HB1003R - Refrigerating Cycle Procedures

LG HB1003R
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disassembly
18 Room Air Conditioner
5. MOTOR
1. Remove the cabinet.
2. Remove the turbo fan.
3. Remove the fan.
4. Remove the 4 screws which fasten the motor from
the air guide. (See Figure 28)
5. Remove the motor.
6. Re-install the components by referring to the
removal procedure, above.(See Figure 28)
1. CONDENSER
1. Remove the cabinet.
2. Remove the 5 screws which fasten the
brace.
3. Remove the 5 screws which fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Figure 29)
2. EVAPORATOR
1. Remove the control box.
2. Remove the air guide upper.
3. Remove the 2 screws which fasten the evaporator.
4. Move the evaporator sideways carefully.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Figure 30)
Figure 28
Figure 29
Figure 30
Refrigerating Cycle
CAUTION: Discharge the refrigerant system using a Freon
TM
Recovery System. If there is no valve
to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon
TM
. Leave
the valve in place after servicing the system.