EasyManua.ls Logo

LG KE820 - Power ON;OFF

LG KE820
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. TECHNICAL BRIEF
- 39 -
3.4. Power ON/OFF
KE820/KG99 Power State : Defined 3cases as follow
] Power-ON : Power key detect ( SM-Power’s ON port)
] Power-ON-charging : Charger detect.
] Power-ON-remote : remote power on detect (Factory use only)
Input ON is a power-on input for SM-POWER with 2 active high levels (see Figure 8). It might be
triggered by a push button or by the RTCOUT output of the S-GOLD device as well. To detect if the
push-button is pressed during system operation the logical level at pin ON or its change (if Bit 1 EION
in INTCTRL2 is asserted) is recorded in bit LON of the ISF register. If the high level of voltage at pin
ON does not reach VIHdet (Vbat-0.8 ~ Vbat-0.3) the above-mentioned bit won’t be set.
To support Remote power on function for factory mass production, applied an analog switch as
following figure. As monitoring the RPWRON(GPIO_110) and Key matrix KP_OUT(1) & KP_IN(5),
KE820/KG99 system recognize whether remote power on or End-key pushed
Figure 8 Power on application.