Installation Manual 11
ENGLISH
Installation of Indoor, Outdoor Unit
Indoor unit installation
Installation of Unit
Install the unit above the ceiling correctly.
Apply a joint-canvas between the unit and duct
to absorb unnecessary vibration.
Apply a filter Accessory at air return hole.
Install the unit leaning to a drainage hole side
as a figure for easy water drainage.
A place where the unit will be leveled and that
can support the weight of the unit.
A place where the unit can withstand its
vibration.
A place where service can be easily
performed.
CASE 1
POSITION OF SUSPENSION BOLT
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local
supply)
X 4
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local
supply)
X 4
CASE 2
POSITION OF CONSOLE BOLT
(Unit:mm)
1282 1230 477 56 590 30 120 1006 294
48 kBtu/h
60 kBtu/h
1232 1180 355 45.5 450 30 87 830 186
30 kBtu/h
36 kBtu/h
42 kBtu/h
Dimension
Capacity
ABCDE F(G)HI