14 | PRODUCT DATA
Single-Zone LGRED° Four-Way Ceiling-Cassette System Engineering Manual
'XHWRRXUSROLF\RIFRQWLQXRXVSURGXFWLQQRYDWLRQVRPHVSHFL¿FDWLRQVPD\FKDQJHZLWKRXWQRWL¿FDWLRQ
©
/*(OHFWURQLFV86$,QF(QJOHZRRG&OLIIV1-$OOULJKWVUHVHUYHG³/*´LVDUHJLVWHUHGWUDGHPDUNRI/*&RUS
Table 5: Functions, Controls and Options.
1
Primary washable filter. 14”x14”x1” for 2x2 units; 20.5”x20.5”x1” for 3x3 units.
2
Requires wired zone controller.
¥ 6WDQGDUGIHDWXUH o = Unit option X = Not Available
FUNCTIONS, CONTROLS, AND OPTIONS
System Type 2x2 Cassette 18K 3x3 Cassette 24K 3x3 Cassette 36K 3x3 Cassette 42K / 48K
$LUÀRZ
Air Supply Outlets
4444
Airflow Direction Control
Auto ¥6L[6WHSV ¥6L[6WHSV ¥6L[6WHSV
Auto Swing (Up and Down)
¥ ¥¥¥
Airflow Steps (Fan / Cool / Heat)
4 / 5 / 5 4 / 5 / 5 4 / 5 / 5 4 / 5 / 5
Jet Cool / Jet Heat (Power Wind)
¥ ¥¥ ¥¥ ¥¥
Swirl Wind
X ¥¥¥
Refresh Mode
X ¥¥¥
Smart Mode
X ¥¥¥
Indirect Wind
X ¥¥¥
Direct Wind
X ¥¥¥
Filters
Long Life Pre-filter (Washable / Anti-fungal)
1
¥ ¥¥¥
Oper.
Drain Pump
¥ ¥¥¥
High Ceiling Operation
2
¥ ¥¥¥
Reliability
Hot Start
¥ ¥¥¥
Self Diagnosis
¥ ¥¥¥
De-ice Control (Defrost)
¥ ¥¥¥
Dry (Dehumidification) Operation
¥ ¥¥¥
Convenience
Auto Changeover
¥ ¥¥¥
Auto Cleaning (Coil Dry)
¥ ¥¥¥
Auto Restart
¥ ¥¥¥
Child Lock
2
¥ ¥¥¥
Forced Cooling Operation (Outdoor Unit)
¥ ¥¥¥
Sleep Mode
¥ ¥¥¥
Timer: 24 hour (On / Off) / 7 hour (Off)
¥¥ ¥¥ ¥¥ ¥¥
Timer: Weekly
2
¥ ¥¥¥
Two Thermistor Control
2
¥ ¥¥¥
Low Ambient Operation
¥ ¥¥¥
Overheating Protection
X ¥¥¥
ODU Silent Mode / Night Low Noise Operation
¥ ¥¥¥
Smart Diagnosis
¥¥¥¥
Indoor Unit Display Type
X One LED One LED One LED
Indoor Unit Display Light
X On / Off On / Off On / Off
Ener.
Sav.
Energy Saving
X ¥¥¥
Energy Control
X ¥¥¥
Netwk.
Func.
Network Solution (LGAP)
¥ ¥¥¥
Controllers
3
Programmable Controllers (MultiSITE CRC1 / +)
o (PREMTBVC0 / PREMTBVC1)
Simple Remote Controller
o (PREMTC00U)
o (PREMTC00U)
3
o (PREMTC00U)
3
o (PREMTC00U)
3
Premium Remote Controller
o (PREMTA000) o (PREMTA000) o (PREMTA000) o (PREMTA000)
Wireless Handheld Remote Controller
¥34:5+4)'% ¥$.% ¥$.% ¥$.%
Remote Temperature Button Sensor
o (ZRTBS01) o (ZRTBS01) o (ZRTBS01) o (ZRTBS01)
Dry Contact
o (PDRYCB100 / 320 / 400)
PI-485
o (PMNFP14A1) o (PMNFP14A1) o (PMNFP14A1) o (PMNFP14A1)
Cntrl. Contl./
Integ. Sol.
AC Smart 5
o (PACS5A000) o (PACS5A000) o (PACS5A000) o (PACS5A000)
ACP 5
o (PACP5A000) o (PACP5A000) o (PACP5A000) o (PACP5A000)
MultiSITE Communications Manager
o (PBACNBTR0A) o (PBACNBTR0A) o (PBACNBTR0A) o (PBACNBTR0A)
MultiSITE VM3
o (PBACNBTR1A) o (PBACNBTR1A) o (PBACNBTR1A) o (PBACNBTR1A)
Special
Function
Aux. Heat Relay Kit
o (PRARH1) o (PRARH1) o (PRARH1) o (PRARH1)
Wi-Fi
3
o (PWFMDD200) o (PWFMDD200) o (PWFMDD200) o (PWFMDD200)
Wind Baffle Kit
¥=/$%*3$ ¥=/$%*3$ ¥=/$%*3$[ ¥=/$%*3$[
Sheath Heater (Drain Pan Heater)
¥ ¥¥¥
Smart Inverter Monitoring System (SIMS)
o (PSWMOZ3) o (PSWMOZ3) o (PSWMOZ3) o (PSWMOZ3)
Other
Mode Lock
Cooling Only or Heating Only
Temperature Control
¥ ¥¥¥
3
Not all controllers can support all features.
Contact your LG representative for details.