- 75 -
9) Water Condensation on Refrigerator Pillar.
1
1-. Reset the refrigerator (unplug
powercord, wait 10 seconds, plug
powercord.
2-. Wait until Compressor operates.
3-. Check the voltage between brown
and blue wires on CON3.
No Checking flow Result & SVC Action
Result SVC Action
110~120VAC Go to step #2
0~10VAC Replace Main PCB.
2
Result SVC Action
Loose Connection Plug correctly, check again
Firmly connected Go to step #3
1-. Remove Cover Hinge of
refrigerator door (left).
2-. Check for loose connection.
3
Result SVC Action
110~120VAC Go to step #4
0~10VAC Replace Refrigerator Unit.
Check Voltage between brown and
blue wires.