EasyManua.ls Logo

LG LFC20770SW - Page 54

LG LFC20770SW
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 53 -
8) Abnormal Defrosting Operation (dH)
1
Check for loose connection in CON2
No Checking flow Result & SVC Action
Result SVC Action
Firmly plugged Go to step #2
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #2
NO: explain to customer.
2
1-. Execute TEST MODE #2.
2-. Check voltage between wires Brown
and Blue as is shown in the picture.
Result SVC Action
110~120VAC Go to step #3
0~10VAC Replace Main PCB
3
1-. Remove Rails and Cover evaporator.
2-. Check for any loose connection in
Defrost Controller assembly or Defrost
Heater.
Result SVC Action
Firmly plugged Go to step #4
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #4
NO: explain to customer.

Related product manuals