9) Abnormal Freezer Fan Motor Operation (FF)
1
Check for loose connection in CON4
No Checking flow Result & SVC Action
Result SVC Action
Firmly plugged Go to step #2
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #2
NO: explain to customer.
2
1-. Reset the refrigerator (Unplug
powercord, wait 10 seconds, plug
powercord.
2-. Execute TEST MODE #1
3-. Check Voltage between wires Gray
and White.
Result SVC Action
11~17VDC Go to step #3
Other Voltage Replace Main PCB
3
1-. Execute TEST MODE #1
3-. Check Voltage between wires Gray
and Purple.
Result SVC Action
2~4VDC Replace Main PCB
Other Voltage Go to step #4