- 65 -
-
3
1-. Unscrew Duct assembly.
2-. Check for loose connection .
No Checking flow Result & SVC Action
4
1-. Disconnect Duct assembly.
Result SVC Action
373.5~456.5Ù Go to step #5
Other Value Change Duct Assembly.
Result SVC Action
Firmly plugged Go to step #4
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #4
NO: explain to customer.
2-. Check resistance value on Duct
Assembly connector, White to Blue and
Red to Yellow.
B
BA
A
NOTE: Measurement “A” and “B” must be within
spec, If “A” or “B” are not mach with the spec,
consider it as “Other Value” condition.