LG LFC20770SW - 6) Poor cooling in Freezer section.

LG LFC20770SW
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 66 -
5
1-. Check continuity between Duct
Assembly receptacle and CON4
connector.
No Checking flow Result & SVC Action
6
1-. Connect CON4 to Main PCB.
2-. Connect Duct assembly with
receptacle.
3-. Execute TEST MODE #1 and check
damper status.
4-. Execute TEST MODE #2 and check
damper status.
Result SVC Action
TEST
MODE #1
Damper
Opened
Check TEST MODE #2 condition.
Damper
Closed
Replace Main PCB
TEST
MODE #2
Damper
Opened
Replace Main PCB
Damper
Closed
Go to step #7
Result SVC Action
Continuity in all wires Go to step #6
No Continuity in any wire Replace refrigerator unit
<Damper Opened> <Damper Closed>