EasyManua.ls Logo

LG LFXS26973 series - Maintenance and Cleaning; General Cleaning Procedures

LG LFXS26973 series
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-46-
Change the
PCB
Cube mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
6
Explain to customer
1
Check the loose connection
LEVER S/W Voltage [V]
CON2
4
th
pin ~ A
(Blue)
Pushing 112~115V
Not
Pushing
0~2V
3
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
LEVER S/W Voltage [V]
CON3 3
rd
pin ~
13
th
pin
Pushing 9~12V
Not
Pushing
0~2V
Change the
PCB
4
Check the resistance value.
Is Geared Motor resistance
144~ 176?
No
Yes
Replace
Geared Motor
Resistance [
Geared Motor 31.1 ~ 42.1
5
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1?
No
Yes
Replace
Geared Motor
Resistance [
Dispenser Motor 9.9 ~ 12.1
Geared Motor
Dispenser Motor
CON2
h
CON1

Other manuals for LG LFXS26973 series