EasyManua.ls Logo

LG LFXS29626 series - Page 78

LG LFXS29626 series
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 78 -
B4. LED blinks five times, then repeats (Locked Piston: A & E Inverters)
Protection Logic
Blink Blink Blink Blink Blink OFF
Protection
logic
Check B
Blink 5 times
(Lock Piston Trip) Check B4
Compressor
Doesn’t work
Repeat
Check Procedure
Reset
Power
Compressor
Doesn’t work
N
Y
Replace
Compressor
Hi side
restriction
N
Y
Sealed
system
Repair
- Purpose: To detect locked piston
- Cause: Lack of oil to the cylinder, cylinder or piston damaged and or restricted discharge.
A Locked Piston can also be caused by foreign materials inside the compressor.
- Logic: Compressor is forced off and tries to restart within 2.5 minutes.
B3. LED blinks three times, then repeats (Stroke Trip)
Protection Logic
Blink Blink Blink OFF
Protection
logic
Check B
Blink 3 times
(No Current Trip) Check B3
Compressor
Doesn’t work
Y
Reset
Power
Y
Y
Harness
Connecting
Check C
Y
Compressor
Damage
Check C
Replace
Compressor
No Connect trip
occur?
Replace
Drive PCB
Repeat
Check Procedure
Fix Harness
N
N
N
N
- Purpose: Prevent over voltage and current detecting connecting error.
- Cause: -. Connecting error of PCB and Comp, Capacitor Harness -. Comp insulation damage
Logic: Compressor is forced off and tries to restart within 40 seconds.
Blink Blink Blink OFF

Other manuals for LG LFXS29626 series

Related product manuals