EasyManua.ls Logo

LG LMXS28596S - Page 39

LG LMXS28596S
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-39-
Freezer Fan Error (IF E)
1
2
Open the freezer door and Check
the air flow. Windy?
No
Yes
Go to 3
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Yes
Change the
Fan motor
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
Go to 4
Fan Motor
TEST MODE 1 Voltage [V]
CON3
10
th
pin ~ 9
th
pin
0V<Voltage<5V
4
Check the Fan Motor voltage
Is Fan Motor voltage 12V?
Yes
Replace
Main PCB
No
TEST MODE 1 Voltage [V]
CON3
12
rth
pin ~ 9
th
pin
12V
5
Check the Fan Motor voltage
Is Fan control signal voltage
between 0V and 5V?
No
Replace
Main PCB
No
7
Explain to customer
CON3
CON3
TEST MODE 1 Voltage [V]
CON3
11
st
pin ~ 9
th
pin
0V<Voltage<5V
Check the Fan Motor voltage
Is Fan feed back voltage
between 0V and 5V?
No
Replace
Motor
No
CON3
- 39 -