LG LRFD25850ST - Drawer, Shelf, and Leveling Adjustments

LG LRFD25850ST
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 13 -
6-2 PTC AND OLP
65
Shows continuity
Open
Normal operation of
Compressor is
impossible or poor.
Separate PTC-Starter
from Compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
Tester.
(Figure 20)
Separate OLP from
Compressor and check
resistance value
between two terminals
of OLP with a Tester.
(Figure 21)
Observation value is
115V/60Hz : 6.8±30%
The resistance value
is 0 (short) or
(open).
Check another
electric component.
Replace OLP.
Replace PTC-
Starter.
Figure 20
Figure 21