3. Open Door Detection Circuit Check
8-2-3 Temperature Sensor Circuit
The resistance of the SENSOR has a ±5% common difference.
Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
- 29 -
Closed 0 V
Open 5 V
Freezer/
Refrigerator Door
Measurement
Location
Pin 4 & 5 of con4 Ref.Door
Pin 5 & 6 of con5 Fre.Door
TEMPERATURE
RESISTANCE OF FREEZER
RESISTANCE OF REFRIGERATOR &
SENSOR
DEFROST SENSOR & ROOM SENSOR
- 20 ˚C (-4 °F) 22.3 K 77 K
- 15 ˚C (5 °F) 16.9 K 60 K
- 10 ˚C (14 °F) 13.0 K 47.3 K
- 5 ˚C (23 °F) 10.1 K 38.4 K
0 ˚C (32 °F) 7.8 K 30 K
+ 5 ˚C (41 °F) 6.2 K 24.1 K
+ 10 ˚C (50 °F) 4.9 K 19.5 K
+ 15 ˚C (59 °F) 3.9 K 15.9 K
+ 20 ˚C (68 °F) 3.1 K 13 K
+ 25 ˚C (77 °F) 2.5 K 11 K
+ 30 ˚C (86 °F) 2.0 K 8.9 K
+ 40 ˚C (104 °F) 1.4 K 6.2 K
+ 50 ˚C (122 °F) 0.8 K 4.3 K