Service Manual 33
Operation
Buzzer Sounding Operation
When the appliance-operation key is input by the remote controller, the short beep-beep- sounds.
When the appliance-pause key is input by the remote controller, the long beep—” sounds.
Air Cleaner Operation
When an air cleaner function is selected during Air Conditioner operation
- Plasma air cleaner function will be operated while in any operation mode with selecting the function.
- The function is to be stopped while it is operating with selecting the function.
When an air cleaner function is selected during operation off
- The function will be only operated.
When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be
stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B)
will be operated again.
Heater Operation
The heater operates during only heating operating mode.
The heater operation need more input-power, so the heater operation will make you pay more elecricity rates.
If the Start/Stop button is pressed during heater operation, the indoor fan will stop and the horizontal vane will
be closed after 15 seconds to cool the heater.
When the intake air temp reaches +3°C above the setting temp, the heater is turned off. When
below the setting temp, the heater is turned on.
Heater ON Temp. Setting Temp.
Heater OFF Temp. Setting Temp.+3°C