19) Over cooling in Freezer section
CHECKING FLOW RESULT & SERVICE ACTION
Check the sensor resistance value in CON 7.
1
2
NO.
5
4
3
Result
Service Action
Go to Step 2
Ok
Abnormal
Check Section 3,
Abnormal Freezer
Sensor.
Refer to temperature chart for Refrigerator Sensor.
Enter to TEST MODE 1 (Press once the TEST S/W
in Main PCB)
Go to Step 3
Remove Cover PCB, then, check voltage in CON 1
as is shown in the picture.
Result
Service Action
Normal
Other
110 ~ 127 Vac
Change PCB
Enter to TEST MODE 2 (Press again the TEST S/W
in Main PCB)
Go to Step 5
Check Voltage in CON 1 as is shown in the picture.
Result
Service Action
Normal
Other
0 ~ 5 Vac
Change PCB
- 112 -