- 77 -
1) Abnormal Freezer Sensor Error
2. Troubleshooting With Error Display
CHECKING FLOW RESULT & SERVICE ACTION
Check for a loose connection in CON6
Result
Service Action
Firmly plugged
Loose
Go to Step 2
1
Unplug connector and check between
White to White as is shown in the picture.
2
Result
Service Action
0 Ù
OFF
Go to Step 3
Go to Step 4
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #1)
Go to Step 6
Temperatures when unit is energized
(Refer to Temperature Chart #1)
NO.
3
1) Remove the Cover Sensor.
2) Cut Sensor and check resistance value.
Result
Service Action
0 Ù
OFF
Change the sensor
Replace Product
Short