EasyManua.ls Logo

LG MS-114ML - RELAY 2; FAN MOTOR; TURNTABLE MOTOR

LG MS-114ML
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMPONENTS TEST PROCEDURE RESULTS
5-10
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
POWER
LEVEL
10% 4 sec 18 sec
20% 6 sec 16 sec
30% 8 sec 14 sec
40% 10 sec 12 sec
50% 12 sec 10 sec
60% 14 sec 8 sec
70% 16 sec 6 sec
80% 18 sec 4 sec
90% 20 sec 2 sec
100% 22 sec 0 sec
Normal: Approx. 65~80
Abnormal: or several
Normal: Approx. 2~4 K
Abnormal: or several
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 2
Relay 1
Power
Transformer

Related product manuals