COMPONENTS TEST PROCEDURE RESULTS
5-10
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
POWER
LEVEL
20% 6 sec 16 sec
40% 10 sec 12 sec
60% 14 sec 8 sec
80% 18 sec 4 sec
100% 22 sec 0 sec
Normal:
Abnormal: ° or several ½
Normal: Approx. 100~200 ½
Abnormal: ° or several ½
NOTE : ¥ A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
¥ MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
¥ WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 1
Relay 2
Power
Transformer
A
B
C
A ~ B A ~ C
30 ~ 50 ½
300~500 ½