Model | ARNU363NJA4.AMBBLUS |
---|---|
Category | Air Conditioner |
Brand | LG |
Product Line | MULTI V |
Cooling Capacity | 36, 000 BTU/h |
Heating Capacity | 40, 000 BTU/h |
Power Supply | 208-230V/60Hz/1 Phase |
Refrigerant | R410A |
Connection Pipes (Liquid) | 3/8 inch |
Connection Pipes (Gas) | 5/8 inch |
Seasonal Energy Efficiency Ratio (SEER) | 18.0 |
Heating Seasonal Performance Factor (HSPF) | 10.0 |
Operating Temperature (Cooling) | 14°F - 118°F |
Guidelines for choosing an optimal installation site for the air handling unit.
Instructions for installing the unit in an upflow configuration with plenum connections.
Procedures and standards for connecting and sealing ductwork to the air handling unit.
Guidelines for installing the unit in a horizontal-left configuration with proper support.
Steps for cutting and preparing refrigerant pipes for connection.
Detailed procedure for connecting refrigerant pipes to the indoor unit.
Guidance on selecting, handling, and storing plumbing materials for refrigerant piping.
Requirements for insulating refrigerant pipes and joints to prevent condensation and heat loss.
Instructions for installing primary and secondary drain lines and traps for condensate removal.
Guidelines for ensuring correct slope and layout of drain piping to prevent backflow and leakage.
Detailed instructions for connecting electrical wiring between the indoor and outdoor units.
Guidance on instructing the customer on operation and maintenance procedures after installation.
Best practices for laying and connecting power and ground wires to prevent issues.
Information on the electric heater feature, including available models and capacities.
Instructions for setting internal DIP switches on the indoor and outdoor units for configuration.
Procedures for configuring multiple indoor units to operate under a group control system.
Details on connecting and configuring wired and wireless remote controllers for unit operation.
Explanation of the model number nomenclature for identifying unit features and specifications.
Information on the sound pressure levels emitted by the unit and related exposure considerations.
Defines the safe limit for refrigerant gas concentration in case of leaks.
Key performance data, including external static pressure and airflow rates for various capacities.
Data on minimum airflow requirements for heater operation and static pressure drop factors.
Details on static pressure drops associated with field-supplied air filters, affecting unit performance.