Service Manual
Heat Pump and Heat Recovery
Variable Refrigerant Flow Outdoor Units
6.0 to 42.0 Tons
SM-MultiV-IV-Air-Outdoor-Units-4-15
Heat Pump
208 / 230V, 60Hz, 3-phase
and
460V, 60Hz, 3-phase
ARUN072BTE4 / ARUN072DTE4
ARUN096BTE4 / ARUN096DTE4
ARUN121BTE4 / ARUN121DTE4
ARUN144BTE4 / ARUN144DTE4
ARUN168BTE4 / ARUN168DTE4
ARUN192BTE4 / ARUN192DTE4
ARUN216BTE4 / ARUN216DTE4
ARUN240BTE4 / ARUN240DTE4
ARUN264BTE4 / ARUN264DTE4
ARUN288BTE4/ ARUN288DTE4
ARUN313BTE4 / ARUN313DTE4
ARUN337BTE4 / ARUN337DTE4
ARUN312BTE4 / ARUN312DTE4
ARUN336BTE4 / ARUN336DTE4
ARUN360BTE4 / ARUN360DTE4
ARUN384BTE4 / ARUN384DTE4
ARUN408BTE4 / ARUN408DTE4
ARUN432BTE4 / ARUN432DTE4
ARUN456BTE4 / ARUN456DTE4
ARUN480BTE4 / ARUN480DTE4
ARUN504BTE4 / ARUN504DTE4
Heat Recovery
208 / 230V, 60Hz, 3-phase
and
460V, 60Hz, 3-phase
ARUB072BTE4 / ARUB072DTE4
ARUB096BTE4 / ARUB096DTE4
ARUB121BTE4 / ARUB121DTE4
ARUB144BTE4 / ARUB144DTE4
ARUB168BTE4 / ARUB168DTE4
ARUB192BTE4 / ARUB192DTE4
ARUB216BTE4 / ARUB216DTE4
ARUB240BTE4 / ARUB240DTE4
ARUB264BTE4 / ARUB264DTE4
ARUB288BTE4 / ARUB288DTE4
ARUB313BTE4 / ARUB313DTE4
ARUB337BTE4 / ARUB337DTE4
ARUB312BTE4 / ARUB312DTE4
ARUB336BTE4 / ARUB336DTE4
ARUB360BTE4 / ARUB360DTE4
ARUB384BTE4 / ARUB384DTE4
ARUB408BTE4 / ARUB408DTE4
ARUB432BTE4 / ARUB432DTE4
ARUB456BTE4 / ARUB456DTE4
ARUB480BTE4 / ARUB480DTE4
ARUB504BTE4 / ARUB504DTE4
Question and Answer IconNeed help?

Do you have a question about the LG MULTI V ARUB144DTE4 and is the answer not in the manual?

Summary

Safety Precautions

Installation

Precautions for safe installation, including handling of equipment and environmental considerations.

Wiring

Electrical safety guidelines, NEC compliance, and proper wiring practices for the unit.

Operation

Safety procedures and precautions during unit operation, including startup and shutdown.

Unit Nomenclature

Basic Controls

Normal Operation; Compressor Control

Details on normal system operation and fuzzy logic-based compressor control for stable performance.

Master-Slave Unit EEVS

Control logic for main and subcooling EEVs in master-slave configurations, including discharge temperature management.

Special Controls

Oil Return Control

Mechanism and operation of oil return control to maintain oil balance in the compressor during cooling and heating.

Defrost Control; Partial Defrost Control

Procedures for defrosting ice on heat exchangers to restore performance and maintain continuous heating operation.

Stop Operation Control

Operating procedures for stopping the unit safely and the function of oil equalizing control between compressors.

Protection Controls

Pressure Protection Control

System responses to high and low pressure conditions to prevent damage and ensure safe operation.

Discharge Temperature Control; Inverter Protection Control

Control strategies for managing discharge temperature and inverter protection mechanisms based on current limits.

Phase Detection; Pressure Switch

Information on phase detection errors and the function of the pressure sensor switch on the main PCB.

Other Controls

Initial Setup

Steps for initial system setup, including factory settings, communication checks, and error checks before operation.

Emergency Operation

Procedures for operating the system during inverter compressor failure using automatic or manual backup functions.

Summary

Safety Precautions

Installation

Precautions for safe installation, including handling of equipment and environmental considerations.

Wiring

Electrical safety guidelines, NEC compliance, and proper wiring practices for the unit.

Operation

Safety procedures and precautions during unit operation, including startup and shutdown.

Unit Nomenclature

Basic Controls

Normal Operation; Compressor Control

Details on normal system operation and fuzzy logic-based compressor control for stable performance.

Master-Slave Unit EEVS

Control logic for main and subcooling EEVs in master-slave configurations, including discharge temperature management.

Special Controls

Oil Return Control

Mechanism and operation of oil return control to maintain oil balance in the compressor during cooling and heating.

Defrost Control; Partial Defrost Control

Procedures for defrosting ice on heat exchangers to restore performance and maintain continuous heating operation.

Stop Operation Control

Operating procedures for stopping the unit safely and the function of oil equalizing control between compressors.

Protection Controls

Pressure Protection Control

System responses to high and low pressure conditions to prevent damage and ensure safe operation.

Discharge Temperature Control; Inverter Protection Control

Control strategies for managing discharge temperature and inverter protection mechanisms based on current limits.

Phase Detection; Pressure Switch

Information on phase detection errors and the function of the pressure sensor switch on the main PCB.

Other Controls

Initial Setup

Steps for initial system setup, including factory settings, communication checks, and error checks before operation.

Emergency Operation

Procedures for operating the system during inverter compressor failure using automatic or manual backup functions.