10 Air Conditioner
Indoor unit
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
Drill a Hole in the Wall
Indoor unit
2. The wall you select should be strong and
solid enough to prevent vibration
• Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using Horizontal
meter .
1. Measure the wall and mark the centerline. It is also important to use caution concerning the
location of the installation plate. Routing of the wiring to power outlets is through the walls
typically. Drilling the hole through the wall for piping connections must be done safely.
Fixing Installation Plate