DIAGNOSTIC TEST
10
Test 1 : ELECTRIC SUPPLY & CONTROL CHECK
Trouble Symptom : No power to the dryer or the controller
Measurement condition : Power is on.
[ Caution] Electric shock. Please test after grounding check.
Power voltage is within
standard range
(AC 215V~245V)?
Check the
- Circuit breaker
Check after disconnecting
Yellow relay and Black relay
connector of Main PCB.
Check the range of Blue and
Brown wire is within AC 215
~245V?
Check the short of
harness assembly and
the connection.
Check or replace the Power
cord.
Check or replace the Noise
filter.
Check or replace the
Controller.