- 19 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
How to Fix Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
four type A screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by align-
ing the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls
typically. Drilling the hole through the wall for
piping connections must be done safely.
ABCD
7K,9K,12K 75 65 105 65
18K, 24K 105 65 260 65
SR2(12K) 0 40 20 40
CHASSIS
(Grade)
Distance (mm)
Installation Plate
Type "A" screw
Chassis
Hook
Installation plat
SR2(12K)
SR2(12K)
e
Left rear piping Right rear piping
Ø70mm
Ø70mm
DB
A
C
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping Right rear piping
C
D
B
A
Ø70mm
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
• Open the Front Grille.
• Pass Telephone Control Cord Wire through the hole
which the power cord goes through.
• Connect Telephone Control Cord Wire to the phone jack
of telephone PCB of Control Box.
• Fix Telephone Control Cord Wire inside Control box so
as not to disconnect.
• Close the Front Grille.
Drill a Hole in the Wall
Drain hose junction
• Remove the rubber stopple in the desired drain direc-
tion.
• Insert drain hose into the handle of drain pan, and join
drain hose and connecting hose according to the figure
by.
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Connecting
part
Adhesive
Drain
hose
Only the
desired direction