INSTALLATION GUIDE AT THE SEASIDE
ENGLISH
If the outdoor unit is to be installed close to
the seaside, direct exposure to the sea wind
should be avoided. Install the outdoor unit on
the opposite side of the sea wind direction.
In case, to install the outdoor unit on the
seaside, set up a windbreak not to be exposed
to the sea wind.
- It should be strong enough like concrete to
prevent the sea wind from the sea.
- The height and width should be more than
150% of the outdoor unit. 
- More than 70cm of space should be kept
between outdoor unit and the windbreak for
easy air flow. 
Place with fluent water draining
- Install at a place with fluent water draining to
prevent damage from localized heavy rain and
avoid frequent flooded area.
SEASONAL WIND AND
CAUTIONS IN WINTER
- Sufficient measures are required in a snow
area or severe cold area in winter so that
product can operate well.
- Get ready for seasonal wind or snow in win-
ter even in other areas.
- Install a suction and discharge duct not to let
in snow or rain.
- Install the outdoor unit not to come in contact
with snow directly. If snow piles up and
freezes on the air suction hole, the system
may malfunction. If it is installed at snowy
area, attach the hood to the system.
- Install the outdoor unit at the higher installa-
tion console by 50cm than the average snow-
fall (annual average snowfall) if it is installed
at the area with much snowfall.
- Where snow accumulated on the upper part
of the Outdoor Unit by more than 10cm,
always remove snow for operation. 
• Periodic ( more than once/year ) clean-
ing of the dust or salt particles stuck on
the heat exchanger by using water.
• Air conditioners should not be installed
in areas where corrosive gases, such as
acid or alkaline gas, are produced.
• Do not install the product where it could
be exposed to sea  wind (salty wind)
directly. It can result corrosion on the
product. Corrosion, particularly on the
condenser and evaporator  fins, could
cause product malfunction or inefficient
performance.
• If outdoor unit is installed close to the
seaside, it should  avoid direct exposure
to the sea wind. Otherwise it needs
additional anticorrosion treatment on the
heat exchanger.
CAUTION
!