EasyManua.ls Logo

LG WD-12111(6)FDB / 12112(7)FDWD-14111FDB - Inlet Valve Assembly

LG WD-12111(6)FDB / 12112(7)FDWD-14111FDB
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Disconnect the wiring connector.
Unscrew 2 screws from the back.
When reconnecting the connector
Cold only model
Cold and Hot model
Remove the back cover.
Unscrew 3 screws.
Disassemble the FILTER ASSEMBLY.
Pull the MAIN PWB ASSEMBLY as shown.
Open the lower cover CAP by using coin and pull out
the lower cover in the arrow direction after a screw is
unscrewed.
1
2
3
Option
INLET VALVE ASSEMBLY
MAIN PWB ASSEMBLY
LOWER COVER
VALVE#1 (MAIN) Whited/Black-Black
VALVE#2 (PRE) Gray/ White - Black
VALVE #1 (MAIN) Whited/Black-Black
VALVE #2 (PRE) Gray/ White - Black
VALVE #3 (HOT) Blue/Red - Black

Related product manuals