23
AC 120V
washing, is the voltage
120 V AC?
Wash/Rinse,
MAIN PWB ASSEMBLY.
Check electrical connection.
Replace THERMISTOR.
Push the THERMISTOR
tightly to the rubber.
When checking THERMISTOR on the tub, is the
THERMISTOR loosened?
Extra Hot : 70°C
Hot : 50°C
Warm : 40°C
Cold : 25°C
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE