Hydraulic System
Item
Specification/Content
Driving
system
Model
Close system
Pump displacement (ml/r)
46
Max working Pressure
(Mpa/psi)
28/4060
Motor displacement (ml/r)
(Front/Rear)
38/38
Functional
system
Model
Open system
Pump displacement (ml/r)
16
Lifting
system
Max working Pressure
(Mpa/psi)
20/2900
Steering
system
Max working Pressure
(Mpa/psi)
13.8/2001
Electrical System
Item
Specification/Content
Battery
Output voltage (V)
12
Capacity (Ah)
120
Control system
Voltage (V)
12
Fueling Capacity
! NOTE: When hydraulic oil and diesel are filled, it is necessary to use the
corresponding hydraulic oil and diesel according to operating environment and
temperature, and refer to the following contents:
Item
Condition
Type
Capacity
Remarks
Hydraulic
oil(L/Gal)
-25Minimum Ambient
temperature
L-HV 32 low
temperature
hydraulic oil
140/37
chevron
-40 Minimum Ambient
temperature ≤-25
L-HS 32ultralow
temperature
hydraulic oil
Minimum Ambient temperature
-40
10# aviation
hydraulic oil
Driving Reducer
oil (L/Gal)
30°CThe lowest temperature
85W/140
0.68×4/
0.18×4
API GL-5
-10°CThe lowest temperature
30°C
85W/90
-30°CThe lowest temperature
-10°C
80W/90
The lowest temperature-30°C
75W
Engine oil(L/Gal)
Working temperature:-20℃~40
15W-40
8/2.1
API CH-4
Working temperature:-25℃~30
10W-30

Table of Contents