System fault diagnosis and fault code-SR69D/SR90D
Main control system Ground
Control Station Error
Replace the Ground Control
Station
Check the wiring, and replace the
upper and lower control units
separately to determine the fault if
the wiring is in a good condition
Just remind the search statues,
not fault
0×10 Pressure Compens
Fault
Unipath voltage-type
compensating-pressure
sensor fault(occur in
machines with two
compensating-pressure
sensors)
Check the wiring and Pressure
sensor
Move the machine to the level
ground
Check the wiring and Angle
sensor
0×0F Pressure sensor fault
Check the wiring and Pressure
sensor
0×14 Chassis Start Sw
Fault
Chassis start switch error
while starting
Check the switch and the wiring
0×15 Chassis Choke Sw
Fault
Chassis Choke opening
error while starting
Check the switch and the wiring
Rising switch opening error
while starting
Check the switch and the wiring
0×17 Chassis Lift Sw Fault
Hoisting switch opening
error while starting
Check the switch and the wiring
0×18 Chassis Down Sw
Fault
Descending switch opening
error while starting
Check the switch and the wiring
Platform left turn switch
opening error while starting
Check the switch and replace the
upper control unit
Platform right turn switch
opening error while starting
Check the switch and replace the
upper control unit
Platform enabling switch
opening error while starting
Check the switch and replace the
upper control unit
0×1C Off Neutral Drive
Joystick
No platform handle in the
middle position while
starting
Check the handle and replace the
upper control unit
0×1D Platform lift Sw Fault
Lifting function key opening
Check the handle and replace the