LGMG North America Inc. Operation and Safety Manual
86
System fault diagnosis and fault code-SR69D/SR90D
Display
Error
code
Description
Solution
01 Internal ECU Fault
01
Main control system Ground
Control Station Error
Replace the Ground Control
Station
02 Platform ECU Fault
02
Communication error
Check the wiring, and replace the
upper and lower control units
separately to determine the fault if
the wiring is in a good condition
07 lockout_two
07
lockout_two
Unlock by the server
09 Search statues
09
Search statues
Just remind the search statues,
not fault
10 Pressure Compens
Fault
10
Unipath voltage-type
compensating-pressure
sensor faultoccur in
machines with two
compensating-pressure
sensors
Check the wiring and Pressure
sensor
0C Tilt alarm LL
0C
Tilt alarm LL
Move the machine to the level
ground
0E Angle sensor fault
0E
Angle sensor fault
Check the wiring and Angle
sensor
0F Pressure sensor fault
0F
Pressure sensor fault
Check the wiring and Pressure
sensor
14 Chassis Start Sw
Fault
14
Chassis start switch error
while starting
Check the switch and the wiring
15 Chassis Choke Sw
Fault
15
Chassis Choke opening
error while starting
Check the switch and the wiring
16 Chassis Up Sw Fault
16
Rising switch opening error
while starting
Check the switch and the wiring
17 Chassis Lift Sw Fault
17
Hoisting switch opening
error while starting
Check the switch and the wiring
18 Chassis Down Sw
Fault
18
Descending switch opening
error while starting
Check the switch and the wiring
19 Left Turn Sw Fault
19
Platform left turn switch
opening error while starting
Check the switch and replace the
upper control unit
1A Right Turn Sw Fault
1A
Platform right turn switch
opening error while starting
Check the switch and replace the
upper control unit
1B Drive Enable Sw Flt
1B
Platform enabling switch
opening error while starting
Check the switch and replace the
upper control unit
1C Off Neutral Drive
Joystick
1C
No platform handle in the
middle position while
starting
Check the handle and replace the
upper control unit
1D Platform lift Sw Fault
1D
Lifting function key opening
Check the handle and replace the