Operation, Maintenance, and Installation Manual | 7612000A
OilTector
®
Control Panel System
Single Phase Simplex | Type 4X (Indoor/Outdoor)
Models: OTC Series, Standard with Remote Alarm
Read all instructions thoroughly. Installation of the OilTector® control system must comply with all federal, state, and local
codes, regulations, and practices. The control system must be installed by qualified personnel familiar with all applicable
local electrical and mechanical codes. Refer to the National Electrical Code (NEC) (NFPA 70). Failure to properly install and
test this product can result in personal injury or equipment malfunction.
The OilTector control system is designed and approved for the safe operation of pumping, alarming, and monitoring of
elevator sump pits, transformer vaults, and leachate well applications. The OilTector control panel will activate a pump to
remove water from elevator pits in accordance with ASME A17.1, stopping the pump before oil or other harmful substances
enter the water supply. The control panel includes LED indicators that will illuminate while monitoring various conditions
including but not limited to: power, pump running, high oil, high water, power loss, level sensor error detection (if enabled),
fire alarm mode (if enabled), and low level alarm/redundant o (if enabled). The included auxiliary contacts will activate
on power loss, high oil, high water, pump running, or the various alarm conditions. These contacts are connected to the
OilTector remote alarm panel which provides audio and visual indication of an alarm condition with built-in auxiliary contacts
for connection to a building automation system (BAS) or SCADA system and phone dialers.
The OilTector control system has configurable features including: level sensor error detection, automatic or manual alarm
condition reset, function input to be used for a fire system or low level/redundant o float switch, and a weekly pump
exerciser. An integrated pump hand-o-auto (HOA) selector switch is included to set the desired operation mode of the
pump and a sensitivity adjustment dial enables fine tuning of the water sensors.
Introduction
Safety Guidelines
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING ON OR HANDLING THE OILTECTOR SYSTEM.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC.
DO NOT USE IN EXPLOSIVE ATMOSPHERES. SENSOR MODULE SHOULD ONLY BE USED WITH WATER.
3. DO NOT HANDLE THE OILTECTOR CONTROL SYSTEM WITH WET HANDS, WHEN STANDING ON A WET OR
DAMP SURFACE, OR IN WATER.
4. INCOMING VOLTAGE MUST MATCH OILTECTOR CONTROL SYSTEM VOLTAGE.
5. TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT MALFUNCTION, USE ONLY WITH A PUMP SUPPLIED
WITH A GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. MAKE SURE TO PLUG THE
OILTECTOR CONTROL PANEL INTO A PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE.
6. CONTROL PANEL CAN BE MOUNTED INDOOR OR OUTDOOR. ALARM PANEL MUST BE MOUNTED INDOOR.
FOR OUTDOOR ALARM APPLICATIONS, CONSULT FACTORY.
7. SECURE THE PRESET LEVEL SENSOR MODULE ON THE DISCHARGE PIPE AT A LEVEL THAT GUARANTEES
PARTIAL PUMP SUBMERGENCE WHEN THE WATER LEVEL IS JUST BELOW THE PUMP STOP PROBE
(longest probe; see step 2 on page 5 of this manual). FAILURE TO PROPERLY MOUNT THE PRESET LEVEL
SENSOR MODULE MAY CAUSE UNINTENDED CONSEQUENCES.
8. CAUTION! REMOVE ANY FLOAT SWITCH THAT IS CURRENTLY USED OR SUPPLIED WITH THE PUMP. IF THE
FLOAT CANNOT BE REMOVED, SECURE FLOAT SWITCH SO THAT IT IS ALWAYS ON.
IMPORTANT
Refer to the included electrical schematic for all incoming power connections and pump connections which may include
optional field wiring connections. This operation and installation manual covers models: OTC-115, OTC-115-5, OTCV-115,
OTC-230, OTC-230-5, OTCV-230, and OTC-230H. System includes: control panel, remote alarm panel, and preset level
sensor module.

Other manuals for Liberty Pumps OilTector OTC-230

Questions and Answers

  • C
    Christopher BrennanJul 25, 2025
    How to troubleshoot a Liberty Pumps Control Panel when the pump does not run?
    • A
      Amanda OrtegaJul 25, 2025
      If the Liberty Pumps Control Panel's pump isn't running, start by ensuring the incoming power cable is plugged in and has power. Check that the pump power cable is connected to the panel receptacle. Also, verify the pump hand-off-auto (HOA) switch is in the HAND or AUTO position, not OFF. Inspect the preset level sensor wiring and connections, and consider replacing the motor contactor or the pump itself if necessary.
  • E
    Erin SharpJul 31, 2025
    What to do if the trouble alarm is activated on my Liberty Pumps Control Panel?
    • M
      Michael ChristensenJul 31, 2025
      If the Liberty Pumps Control Panel's trouble alarm is activated, the pump might be clogged or defective. Begin by removing any debris from the pump. Then, check the pump to ensure it's operating normally. If the problem persists, you may need to replace the pump.
  • M
    Michael KhanAug 6, 2025
    Why does my Liberty Pumps Control Panel pump run continuously?
    • J
      Janet AndersonAug 6, 2025
      If your Liberty Pumps Control Panel's pump runs continuously, the hand-off-auto (HOA) switch might be in the HAND position. Toggle the HOA selector switch to OFF or AUTO. Also, check the preset level sensor wiring and connections, ensuring they are properly seated.
  • Y
    yherringAug 11, 2025
    What to do if the high oil alarm is activated with no oil present in my Liberty Pumps Control Panel?
    • E
      Edwin ValenzuelaAug 12, 2025
      If the high oil alarm is activated on your Liberty Pumps Control Panel but there is no oil present, check the preset level sensor installation, referring to the installation and wiring information. Also, inspect the sump basin for obstructions that might be affecting the high-level float switch. Clear any obstructions so the high-level float switch can operate properly; the alarm condition should clear when the float switch is deactivated.
  • J
    Jason PalmerAug 18, 2025
    Why does the Liberty Pumps Control Panel pump turn off too soon?
    • J
      John WilsonAug 19, 2025
      If the Liberty Pumps Control Panel's pump turns off too soon, it might be due to a poor pump or system ground. Check the grounding system and wire terminations. Another potential cause is a dirty or damaged preset level sensor. Try cleaning or replacing the preset level sensor.

Summary

Safety Guidelines

Description of Operation

Level Sensor Error Detection

Monitors for incorrect probe activation sequence, indicating faulty wiring or sensor.

Automatic Alarm Reset

Alarms reset automatically when the condition clears; manual reset requires button press.

OilTector Control Panel Installation

Preset Level Sensor Installation

System Wiring | Preset Level Sensor

Details wiring connections for the preset level sensor probes to the control panel.

Device Configuration Settings

Water Sensor Sensitivity Settings

Pump HOA Selector Switch Settings

Alarm Panel Installation

Alarm Panel Installation Details

Alarm Panel Testing

Control Panel System Testing

Basic Troubleshooting

Liberty Pumps OilTector OTC-230 Specifications

General IconGeneral
BrandLiberty Pumps
ModelOilTector OTC-230
CategoryControl Systems
LanguageEnglish

Related product manuals