24
Electrical connection
Before connecting the product, check that the systems comply with the regulations in force in the country of use and as stated
on the rating plate located on the right side of the oven.
The mixer is provided with a power cable with SCHUKO plug in single-phase version, without plug in the three-phase versions.
The connection to the power network must be performed by interposing a differential circuit breaker switch having suitable
features, and minimum opening distance between the contacts of at least 3 mm.
In the single-phase version it is sufficient to connect the machine to the electrical socket. In the three-phase version you need
to apply a 4-pole 400V - 16A plug (not supplied); the electrical connection must be carried out exclusively by qualified and
specialized personnel.
FOR THREE-PHASE MIXERS, CHECK THE CORRECT DIRECTION OF THE TANK ROTATION
(CLOCKWISE). IF IT TURNS IN THE OPPOSITE DIRECTION, REVERSE TWO PHASES IN THE PLUG OF
THE MACHINE.
ALSO FOLLOW THE PROVISIONS GIVEN BELOW:
• The mains socket must be easily accessible and should not require moving the mixer.
• The electrical connection must be easily accessible even after the mixer has been installed.
• The distance between the mixer and the socket must be such not to have the power supply cable stretched.
• If the power cable is damaged, have it replaced by the technical assistance service or by a qualified service technician in
order to prevent any risk.
• For any product returns, we recommend the use of the original packaging (which will be kept) and the removal of the
wheels if present.
Earthing
It is mandatory for the system to be provided with an earthing system.
According to the regulations in force, it is required to connect the equipment to an equipotential system whose efficiency must
be properly verified as prescribed by the rules in force.