EasyManua.ls Logo

Liebert HIMOD S series User Manual

Liebert HIMOD S series
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Liebert HIMOD S series and is the answer not in the manual?

Liebert HIMOD S series Specifications

General IconGeneral
BrandLiebert
ModelHIMOD S series
CategoryAir Conditioner
LanguageEnglish

Summary

Features and Benefits

Energy Efficiency

Discusses energy efficiency improvements with EC fans and optimized components.

Plug-in Fan

Details the centrifugal plug fans with backward curved blades used in HIMOD units.

EC Fan

Explains the benefits of Electronically Commutated Fans (EC Fans) for increased efficiency.

Easy maintenance

Highlights the accessibility of components for simplified maintenance and service.

Model Configuration

Digit Nomenclature

Explains the seventeen-digit nomenclature used to define the unit's configuration.

Air Distribution (4th Digit)

Illustrates the four available air distribution configurations (Under, Over, Displacement, Grille).

Version A: Direct expansion units with air-cooled condenser

Details the refrigeration circuit and external air-cooled condenser for Version A.

Version W: Direct expansion units with water-cooled condenser

Explains the refrigeration circuit and water-cooled condenser for Version W.

Version F: Freecooler units

Describes the freecooling mode, refrigeration circuit, and water-cooled condenser for Version F.

Version D: Air-cooled condenser dualfluid units

Details the dualfluid modes, refrigeration circuit, and external air-cooled condenser for Version D.

Version H: Water-cooled condenser dualfluid units

Explains the dualfluid mode, refrigeration circuit, and water-cooled condenser for Version H.

Version C: Chilled water units

Describes the chilled water circuit and the 3-way modulating valve used in Version C.

Constant K/L

Discusses Constant units for precise temperature and humidity control with tight tolerances.

Displacement D: Top air inlet, Front air discharge

Describes the displacement units, their advantages, and suitability for high specific load applications.

Operating Range

Technical Data

Airflow characteristics

Sound Pressure Level

Silencing cartridges (option)

Describes silencing cartridges as an option to reduce sound levels.

Technical Specifications

Refrigerant (DX units only)

Discusses refrigerant types (R407C, R22) and their properties.

Compressor (DX units only)

Details the SCROLL compressors used in DX units, including COP and MTBF.

Filter section

Microprocessor Controls

Microface Evolution (std)

Introduces the standard Microface Evolution control system and its user interface.

Humidification

All Options / Accessories

Heating, Reheat, and Humidity Control

Covers options for controlling heating, reheating, and humidity.

Humidifier

Details the humidifier option.

Refrigerant and Hydraulic Circuits

Service

Related product manuals