Removal from storage
Before reusing, service the engine in accordance with the instruction of the table
(1) Screw off the drain plug and drain out fuel in the carburetor.
(2) Turn off the engine switch first, disconnect the deposit cup and empty it.
Note: for the sake of environmental protection, we recommend to fill the discarded fuel into a closed container
and bring to local recycling station. Never pour freely.
WARNING:
Fuel is extremely flammable and explosive under certain conditions. Keep cigarette, open flames and
sparks away from operating site.
STORAGE TIME
SERVICE ITEM
Within one month
Non
One ~ two months
Drain out original fuel of the fuel tank and refuel
Two month ~one year
Drain out original fuel of the fuel tank and refuel;
Drain out fuel in the carburetor;
Empty the deposit cup
Above one year
Drain out original fuel of the fuel tank and refuel;
Empty the fuel cup in the carburetor;
Empty the deposit cup