Fig. (1)
AC017
3
2
1
Fig.1.2
Fig.1.1
Fig.1.3
ECU - 24 V d.c.
V
V
1,1
1,2 1,4
µF
14
14 16
N
500 700 900
Type
°C
140
NO
10 nim/m
4
min
10
20
°
44 / 55**
D
F
170 (plate) x 342 x 288 (h) mm / 10 kg
Max gate weight
kg
400 600 800
150
150
6
6
6/12
11
10
300
600
ECU - 230 Vca 50
AC3RM24DL AC6RM24DL
RG1R 24 DL
RG1R 24 DL
NO
500
300
48
NO
AC12R DL
RG1R DLRG1R DL
RG1R DL
RG1R DL
AC4R DL
AC6R DL
AC8R DL
350
1,6
16
1200
8
1200
IP
grassograsso
grasso
olioolio
grasso
Built-in ECU
Power supply
Motor power supply
Motor power
Power input from mains 230V / Max. absorption at pick-up 24 V
Capacitor
Thrust
Lubrication
Thermal protection device
Limit switch
Encoder
Speed
External toothed wheel module
Number of teeth external toothed wheel
Work cycle
Nominal work time
Battery recharge time (optional)*
Opening cycles with charged battery*
Operating temperature
Protection class
Motor insulation class
Assembly
Dimensions / weight
Dont use in acid, saline or potentially explosive environment
Version:
ACER: Irreversible electromechanical opera
2 electromechanical or magnetic limit switches in M version
optical
magnetic
BATTERY NOT PROVIDED
BATTERY NOT PROVIDED
C
from -20 a +70
from -20 a +70
horizontal with dedicated anchorage plate
LIFE home integration reserves the right to make changes to technical characteristics at any time and without prior notice, without changing its intended
use and function.
TECHNICAL FEATURES
* For 2 Ah batteries (optional and installed).
Attention:
The activation of the manual release could cause an uncontrolled movement of the gate in the event of mechanical damage or unbalanced
conditions.
To avoid breaking the key, do not apply excessive force.
d) The operator is now free and can be moved by hand. A microswitch assembled on the blockage device prevents the motor from operating when
the power comes back on.
e) To reconnect the transmission, turn the opposite way and move the gate manually until it hitches up.
1.1 Operator release
1.0 INSTALLATION
44 / 55**
** Protection class for magnetic limit switch
230 Vac 50 Hz
230 Vac 24 Vdc
W
250
380
300
A
AC15RM DL
RG1R DL
400
16
1.6
1500
olio
16
16
18
tor for sliding gates with optical/magnetic encoder and built-in ECU
% 35
50
80
20
1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LIFE home integration AC 8R DL and is the answer not in the manual?

LIFE home integration AC 8R DL Specifications

General IconGeneral
BrandLIFE home integration
ModelAC 8R DL
CategoryGarage Door Opener
LanguageEnglish

Related product manuals