Questions and Answers

  • M
    Michael CostaAug 15, 2025
    What to do if I see a flashing light on my Lifebreath HRV RNC6 ES Fan timer or main control?
    • W
      William SimmonsAug 15, 2025
      A flashing light usually indicates a wiring, voltage, or communication error. Try cycling the power by turning the unit off and disconnecting it for 30 seconds, then reconnect and turn it back on. If the problem continues, it is recommended to contact your service contractor.
  • C
    Christine LeeAug 18, 2025
    Why are my Lifebreath Fan's humidity levels too high, and condensation is appearing on the windows?
    • E
      Earl LeeAug 18, 2025
      High humidity and condensation can occur if: * The dehumidistat is set too high. * The HRV isn't sized for a hot tub or indoor pool. * There's unvented moisture from a crawl space. * Moisture remains in washrooms and kitchens. * It's spring or fall, with humid days. * The HRV speed is too low. To address this: * Lower the dehumidistat setting. * Cover pools and hot tubs when not in use. * Avoid drying clothes indoors or storing wood inside. * Vent the crawl space and add a vapor barrier. * Ensure effective ventilation in washrooms, using a fan if needed. * Understand that some condensation is normal during seasonal changes, but the HRV will maintain air quality.
  • B
    Bruce CooperAug 21, 2025
    What to do if my Lifebreath HRV RNC6 ES Fan has poor airflow?
    • B
      Brian SnowAug 21, 2025
      Poor airflow can be caused by several factors: * Blocked mesh on the outside hood. * Plugged filters. * Obstructed core. * Closed or blocked house grilles. * Closed dampers (if installed). * Poor power supply. * Restricting ductwork. * Improper speed control setting. * Improperly balanced HRV airflow. To resolve this: * Clean exterior hoods or vents. * Remove and clean the filter. * Remove and clean the core. * Check and open grilles. * Open and adjust dampers. * Have an electrician check the supply voltage. * Check duct installation. * Increase the speed of the HRV. * Have a contractor balance the HRV.
  • A
    Andrea StephensAug 25, 2025
    Why does the supply air from my Lifebreath HRV RNC6 ES feel cold?
    • H
      Hannah SotoAug 25, 2025
      Cold supply air can be due to the location of supply grilles causing irritation or extremely cold outdoor temperatures. Try locating the grilles high on the walls or under the baseboards, or installing ceiling-mounted diffusers or grilles to avoid direct airflow on occupants. You could also turn down the HRV supply speed or use a small duct heater (1kW) to temper the supply air. Ensure furniture placement or closed doors aren't restricting air movement. If the supply air is ducted into the furnace return, the furnace fan may need to run continuously to distribute ventilation air comfortably.
  • W
    warrendanielAug 27, 2025
    What to do if my Lifebreath Fan's dehumidistat is not operating?
    • J
      John SummersAug 27, 2025
      If the dehumidistat isn't working, it could be due to the outdoor temperature being above 15°C (59°F), an improper low voltage connection, or an external low voltage short caused by a staple or nail. The dehumidistat functions normally above this temperature. Check that the correct terminals have been used and inspect the external wiring for shorts. Also, ensure the dehumidistat is set to the desired setting.
  • D
    Dustin DavisAug 30, 2025
    Why are the humidity levels too low in my house with a Lifebreath HRV RNC6 ES?
    • D
      Daniel MacdonaldAug 30, 2025
      Low humidity levels can be caused by a dehumidistat control set too low, the blower speed of the HRV being too high, the lifestyle of the occupants, or improperly balanced HRV airflows. You can try setting the dehumidistat higher, decreasing the HRV blower speed, adding humidity using humidifiers, or having a contractor balance the HRV airflows.
  • M
    Mr. Daniel Flores IIISep 2, 2025
    What causes condensation or ice buildup in the insulated duct of my Lifebreath HRV RNC6 ES to the outside?
    • D
      Dustin MendozaSep 2, 2025
      Condensation or ice buildup in the insulated duct can be caused by an incomplete vapor barrier around the insulated duct or a hole/tear in the outer duct covering. To fix this, tape and seal all joints, tape any holes or tears in the outer duct covering, and ensure the vapor barrier is completely sealed.
  • J
    Joshua KeySep 5, 2025
    Why are my HRV and/or ducts frosting up with my Lifebreath Fan?
    • B
      Blake GregorySep 5, 2025
      HRV and/or ducts frosting up can be caused by improperly balanced HRV airflows or a malfunction of the HRV defrost system. To address this, have an HVAC contractor balance the HRV.
  • W
    Wayne AndersonSep 8, 2025
    Why is there excess water in the bottom of my Lifebreath Fan HRV?
    • C
      cody62Sep 8, 2025
      Excess water in the bottom of the HRV can be caused by plugged drain pans, an improper connection of the HRV's drain lines, the HRV not being level, obstructed drain lines, or the HRV heat exchange core not being properly installed. Look for obstructions or kinks in the drain line.
  • P
    Paul Williams Jr.Sep 12, 2025
    What causes excessive vibration in my Lifebreath HRV RNC6 ES?
    • W
      Wendy ThompsonSep 12, 2025
      Excessive vibration can be caused by dirt on the fan wheels. It is recommended to have a contractor service the HRV.

Summary

Controlling Your HRV

Selecting Ventilation Settings

Main Wall Controls

Ventilation Wall Control (99-BC02)

Operating instructions for the 99-BC02 wall control unit.

Ventilation Wall Control (99-BC03)

Operating instructions for the 99-BC03 wall control unit.

Ventilation Wall Control (99-BC04)

Operating instructions for the 99-BC04 wall control unit.

Digital Wall Control (99-DXPL02)

Operating instructions for the digital wall control unit 99-DXPL02.

Timers and Repeaters

Maintenance Instructions

Troubleshooting

Flashing Light on Timer;Control

Troubleshooting for flashing indicator lights on timers or main controls.

Poor Airflows

Diagnosing and resolving issues related to low or obstructed airflow.

Dehumidistat Not Operating

Troubleshooting steps when the dehumidistat function is not working correctly.

High Humidity;Condensation on Windows

Solutions for excessive indoor humidity and condensation on windows.