Corrected splash screens are included in this release. (END-20432)
sshd now starts properly when the video system is configured for VLAN. (END-20383)
Disconnecting a system registered to a gatekeeper from one not registered to a gatekeeper no longer results
in the orange indicator remaining as connected and the device being unavailable. (END-20240)
After upgrading from v4.8.x to 4.9.0, the Video Call Audio Output preference was automatically changed to
HD Out resulting in a loss of audio. This no longer occurs in this release, however, if you experience a loss of
audio after upgrading, ensure this preference is set to HD Out and/or Line Out. (END-20163)
Choose Disabled for the Retain DHCP IP Address preference to clear the most recently assigned DHCP IP
address and to request a new one. (END-20118)
DNS lookup no longer fails for calls outside the network calling in using SIP URI via LifeSize Transit. (END-
20011)
FECC is now operating correctly in two way calls with long durations. (END-19899)
You can now successfully dial LifeSize Connections numbers from the corporate directory using the CLI.
(END-19894)
Special characters are allowed in the system name in this release
(Preferences:System:Identification:System Name). (END-19859, END-19875)
When entering data in Preferences : Communications : SIP for the authorization name, a backslash is no
longer appended to the field causing registration failures. (END-19724)
Far end recording occurs as follows:
- if the recording device is in a two way call only the remote end is recorded
- if the recording device is a participant in a multi-way call, all callers are recorded.
- if the recording device is hosting a multi-way call, only the far end last speaker is recorded, which is new
in this release. (END-19709)
Calls between LifeSize systems and Microsoft Lync no longer fail while showing
(END-19696)
When entering a host name in the NAT Public IP address preference, up to 62 characters are now accepted.
(END-19658)
SNMP monitor tool crash issues have been addressed in this release. (END-19619)
PHP version 5.3.10 is included in this release to address security vulnerabilities. (END-19488, 18916, 18984)
The web administration interface now recognizes a change to the autosh password immediately without
requiring a reboot. (END-19100)
Connecting LifeSize Desktop clients registered to Lync no longer fails. (END-19061)
You can now change the far end source from VGA to main camera. (END-18810)
Router solicitations are now disabled when IPv6 is disabled or set to manual configuration. (END-18685)
-18223)
OCS registration is now successful and no longer fails after an OCS call connects. (END-18155)
Video no longer fails during long calls to Radvision Elite 5110 MCUs. (END-18025)
Failures due to data corruption on the internal flash memory device are addressed in this release. Specifically,
when powering on the system and it appears to boot normally but displays the initial configuration screen, the
flash device is functioning properly but file system damage in the data partition has occurred and many or all
preferences have been reset to the factory default values. This release protects against this condition,
allowing the system to restore the last customized value of preferences even if the data partition of the flash is
damaged. You must upgrade to this release prior to this failure occurring for protection against this issue.
(END-17640)