Questions and Answers

  • J
    jacksonamandaAug 13, 2025
    How to troubleshoot no 4-20mA signal on Limaco Transmitter?
    • K
      Katie WilliamsAug 13, 2025
      If the Limaco Transmitter shows no 4-20mA signal, first, check the power supply and electrical connections to ensure they are within acceptable values. If the connection is damaged or the line resistance is too high, restore the connection or reduce the load. If the problem persists, the electronic unit may be malfunctioning, requiring the device to be sent for repair.
  • A
    Amanda GrayAug 16, 2025
    What to do if 4-20mA signal corresponds to alarm values in Limaco ULM-3D Transmitter?
    • K
      Kristin DeanAug 16, 2025
      If the 4-20mA signal on your Limaco Transmitter corresponds to an alarm value, it indicates that one or more monitored parameters are outside of tolerance. Use a PC or console to connect to the level transmitter and check the match between the alarm value and its mask. Other potential causes include temperature outside the acceptable range (eliminate overheating, isolate from high temperatures, provide cooling, or install a sun visor), deviation from the vertical axis (align the device), or a meter malfunction (send the device for repair). It can also be caused by the lack of stability of readings. In this case, a reference parameter operation can be continued, or unstable mode. In this case you should contact the technical support.
  • D
    dbrooksAug 20, 2025
    What to do if 4-20 mA signal does not correspond to the actual value of the monitored variable in Limaco ULM-3D Transmitter?
    • K
      kathy24Aug 20, 2025
      If the 4-20 mA signal from your Limaco Transmitter doesn't match the actual monitored value, it could be due to a malfunction in the electronic unit. Check the current signal performance by emulation. If it doesn't conform, send the device for repair. Another cause could be incorrect initial settings or violated installation requirements. In this case, make spectrum recordings and send them to technical support for further recommendations.
  • V
    Victoria BakerAug 25, 2025
    Why Limaco ULM-3D has no output signals?
    • W
      William AndersonAug 25, 2025
      If your Limaco Transmitter has no output signals, it could be due to damage to the cable network. Check and restore the electrical connection. Another cause could be an electronic unit failure, in which case you should dismantle the device and send it to the manufacturer for repair.
  • L
    Linda SchmidtAug 28, 2025
    How to fix no RS-485 connection with 4-20 mA signal on Limaco ULM-3D?
    • R
      Robert Mcdonald Jr.Aug 28, 2025
      If there is no RS-485 connection in the presence of a 4-20 mA signal in your Limaco Transmitter, verify the electrical connection of the line. Restore the line or ensure it complies with the requirements and connection diagram.
  • L
    Lisa WhiteAug 31, 2025
    What to do if Limaco ULM-3D Transmitter has no RS-485 connection, but 4-20 mA signal is present and communication line is OK?
    • M
      Melissa FranklinSep 1, 2025
      If you have no RS-485 connection with a 4-20 mA signal and the communication line is in good working order for your Limaco Transmitter, the issue might be with the USB/RS-485 converter settings or driver installation. Check the converter's operation in the Device Manager and adjust the settings as needed. It could also be due to incorrect Modbus addresses; ensure each level transmitter on the line has a unique address and specify the correct number in the Configurator software. Lastly, check if another application is using the COM-port, and if so, close it and restart your PC if necessary.
  • M
    marcuspetersonSep 5, 2025
    What causes mechanical damage to the housing of Limaco Transmitter?
    • G
      garciajudySep 5, 2025
      Mechanical damage to the housing of your Limaco Transmitter, such as dents, cracks, or damage to threaded connections, is likely due to damage during installation. If the explosion protection is compromised, the product must be replaced.
  • J
    Jared BrownSep 8, 2025
    What causes mechanical damage to the cable gland of Limaco ULM-3D Transmitter?
    • W
      William AllenSep 8, 2025
      Mechanical damage to the cable gland of your Limaco Transmitter, such as dents, cracks, or damage to threaded connections, is likely due to damage during installation. Products that cannot be restored are subject to replacement.